Habitation Service

Habitation
Detailed Damp Report
A comprehensive and detailed damp report will be complied using a digital damp test meter and issued with an explanation and diagram of the findings. This detailed report will highlight any areas of concern and possible remedies required, and give a yearly oversight and an early warning of any future possible issues regarding damp.
Water Systems and associated appliances checks
- All systems pipework and associated appliances inspected and tested
- Operation and condition of water pump
- Operation of pressure switch and adjust if required
- Condition of water filter and housing
- Operation of taps and shower fittings (including external taps if fitted)
- Inspect overall condition of fresh and waste water pipes and fittings
- Toilet operation and condition of seals, blade and flush
- Drain plugs for seal and operation (Drain down system)
Electrical Systems Inspections 240v
- Condition of inlet plug/ hook up cable
- Operation of RCD, MCB's and earth bonding
- Wiring, sockets and fixed connections
- Operation of battery charger
- Mains operation of fridge
- Check mains operation of cooker/hob
- Operation of water heater
- Mains operation of space heater
Electrical Systems Inspections 12v
- Condition of wiring, sockets and fuses
- Operation of lights including awning light
- Blown air system
- Condition of 12N and 12S or 13pin plugs and cables
- Condition and operation of road lights and reflectors
- Functions of 12S system (charging, fridge, lights etc)
General Inspections
- Security and integrity of body attachment to chassis
- Condition, integrity/security of all bodywork and panels
- Operation of door locks, catches and hinges lubricate and adjust where required
- Condition and security of all trims, inserts and sealants
- Windows and seals for damage or possible water ingress
- Security of grab handles
- Security of body attachments (ladders, aerials, cycle racks etc)
Gas Supply /Appliances inspections & operational Checks
Please note gas appliances have a Flame Failure Device known as FFD. The FFD is designed to shut off the gas supply should ignition fail or the flame be extinguished during use.
- Gas tightness checking for potential leaks in appliances or pipework
- Regulator date, performance, leak
- Inspect condition/date of flexible hose
- Condition/security of all pipe work
- Check for/condition of LPG sticker on gas locker
- Check gas dispersal vents
- Check operation of cooker, hob and oven. Ignition, flame, and FFD
- Check fridge ignition, FFD and cooling
- Check operation of space heater. Ignition, flame and FFD
- Check operation of water heater. Ignition, flame, FFD and heating
- Check operation and condition of external gas point if fitted
- CO Room Test (Room Sealed Appliances Only)
Fire and safety Inspections
- Check position and operation of smoke and CO alarm
- Condition, type and expiry date of fire extinguisher
- Condition and location of fire blanket
- Check operation, function and safety of DIY addition
General Inspections
- Security and integrity of body attachment to chassis
- Condition, integrity/security of all bodywork and panels
- Operation of door locks, catches and hinges lubricate and adjust where required
- Condition and security of all trims, inserts and sealants
- Windows and seals for damage or possible water ingress
- Security of grab handles
- Security of body attachments (ladders, aerials, cycle racks etc)